Bradford White SW-2-30-L

The Bradford White SW-2-30-L is a 29 US gallon (110 L) single-wall indirect water heater rated for 197 US gallons of first-hour delivery at 135 °F against a 120,000 BTU/h heat source, sold in Canada through wholesale channels. A boiler, not a burner, heats its coil.

CurrentSold in Canada

Key figures

Nominal capacity
29 US gal (24 Imp. gal, 110 L)
First-hour delivery
197 US gal (746 L)
Input
Efficiency
Natural gasPropaneElectricVenting unknownresidential

Nominal volume, rated volume and first-hour delivery are different figures; size by first-hour delivery.

Bradford White SW-2-30-L in practice

The SW-2-30-L is the smallest of the Canadian PowerStor single-wall indirect line, sized for homes where a boiler already exists and a compact potable tank is wanted beside it. Its AHRI rating of 197 US gallons (746 L) of first-hour delivery at 135 °F shows how a boiler-fed coil turns a small tank into a large delivery figure, because the boiler reheats the tank continuously while water is drawn.

The rating is conditional: the sheet pairs it with a minimum 120,000 BTU/h heat source, and the actual delivery follows the boiler's output and priority control. Single-wall construction and the potable-water role mean the boiler fluid and domestic water are separated by one metal wall, which is a code consideration in some jurisdictions. Whether CANRO supplies this tank for a job is confirmed at consultation.

Best suited to

  • Homes with an existing boiler where a compact indirect tank fits beside it
  • High-recovery potable supply without a second burner or flue
  • Boiler-replacement projects adding domestic hot water to the hydronic design

Limitations to know

  • Requires a suitable boiler with the output the rating assumes
  • Single-wall coil: double-wall separation is the PowerStor2 alternative where required
  • Hot water depends on the boiler being in service
  • Sizing and control are hydronic design work, not catalogue lookup

Applicability and support

Model number
SW-2-30-L
Variants on this page
None
Canadian availability
available
Production status
current
CANRO supplies
Confirmed at consultation
CANRO services
Confirmed at consultation
Recirculation
Yes, external pump and piping required
Warranty
Series terms

An indirect tank can serve a recirculation loop with an external pump and return connection; the loop is designed at consultation with the boiler controls.

Where CANRO provides on-site service

On-site service is currently offered across Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, Maple Ridge, Pitt Meadows, White Rock, Tsawwassen; plus Anmore, Belcarra, Lions Bay, Bowen Island, Abbotsford with travel or ferry arrangements confirmed by phone. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Bradford White. Manufacturer gallon and BTU/h figures are preserved with metric alongside; notes flag conflicting documents and missing figures. Groups expand for detail.

Storage capacity 1
Bradford White SW-2-30-L specifications: Storage capacity
SpecificationValueNote
Rated nominal capacity29 US gal (24 Imp. gal, 110 L)Canadian sheet C554. Nominal, not the tested storage volume.
Delivery and recovery 2
Bradford White SW-2-30-L specifications: Delivery and recovery
SpecificationValueNote
First-hour delivery at 135 °F (57 °C)197 US gal (746 L)AHRI indirect rating on the sheet, tied to the stated minimum heat source; not comparable with direct-fired first-hour ratings.
Continuous draw rating at 135 °F (57 °C)180 US gal/h (681 L/h)Per the sheet's AHRI table.
Flow (tankless) 1
Bradford White SW-2-30-L specifications: Flow (tankless)
SpecificationValueNote
Coil flow rate13.7 US gal/min (51.8 L/min) at not a heating rise: coil capacity limit riseMaximum flow the sheet lists for the coil circuit.
Connections 2
Bradford White SW-2-30-L specifications: Connections
SpecificationValueNote
T&P connectionFactory-tapped; relief valve fitted at installation
Water connectionsPotable connections per the sheet's typical configurationThe sheet shows typical potable connection layout for the family.
Physical 3
Bradford White SW-2-30-L specifications: Physical
SpecificationValueNote
Height to top of heater33 5/8 in (854 mm)
Jacket diameter22 in (559 mm)
Shipping weight164 lb (74 kg)
Operating limits 1
Bradford White SW-2-30-L specifications: Operating limits
SpecificationValueNote
Minimum output rate of heat source120,000 BTU/h (35.0 kW)Minimum boiler output the sheet pairs with this tank for the rating.
Other 1
Bradford White SW-2-30-L specifications: Other
SpecificationValueNote
Anode rodAnode configurations listed per model on the sheet

Manuals

Maintenance the manufacturer specifies

  • Inspect the anode rod periodically and replace when depleted; more often with softened water.
  • Operate the T&P relief valve at least once a year to check it lifts and reseats without leaking.
  • Have the boiler-side and potable-side service done together: coil performance depends on both systems.
  • Check the mixing-valve setting against the 49 °C fixture limit where one is fitted.

Fault codes documented for this model

None documented yet.

Services

Hot water and scalding

  1. Water above 49 °C at a tap can scald in seconds, and children and older adults are at most risk. BC's plumbing code limits shower and bathtub water to 49 °C.
  2. Storage tanks are normally kept hotter (Health Canada advises 60 °C) to limit Legionella growth, with a thermostatic mixing valve tempering the water to the fixtures.
  3. Never bypass or remove a mixing valve, thermostat or high-limit control to get hotter water.

Official guidance: Government of Canada on water temperature and scalds and HealthLinkBC.

Frequently asked questions

Is the SW-2-30-L sold in Canada?

Yes. The PowerStor single-wall family is listed on Bradford White's Canadian pages with spec sheet C554. Bradford White sells only through wholesalers, so it is supplied and installed by contractors such as CANRO.

How can a 29-gallon tank deliver 197 gallons in an hour?

Because the boiler keeps reheating the tank through the coil while water is drawn; the first-hour figure assumes the rated heat source, not the tank alone.

Does the tank need its own venting?

No. There is no burner at the tank; the boiler that feeds it carries the combustion and venting.

Questions about the Bradford White SW-2-30-L?

Describe what the water heater is doing and get a straight answer about the next step.

On-site service in Metro Vancouver, BC. Call to check availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

Call 604-359-1081Get Estimate