Bradford White · AeroTherm Series G2 hybrid heat-pump water heater · Heat-pump water heater
Bradford White RE2HP6510
The Bradford White RE2HP6510 is a 65 US gallon (246 L) AeroTherm Series G2 hybrid heat-pump water heater with a UEF of 4.20, an 82 US gallon first-hour rating and 4,000 W/3,000 W backup elements, sold in Canada through wholesale channels. It is the middle size of the Canadian G2 range.
Key figures
- Nominal capacity
- 65 US gal (54 Imp. gal, 246 L)
- First-hour delivery
- 82 US gal (310 L)
- Uniform Energy Factor (UEF)
- 4.2
Nominal volume, rated volume and first-hour delivery are different figures; size by first-hour delivery.
Bradford White RE2HP6510 in practice
The RE2HP6510 is the 65-gallon member of the AeroTherm Series G2 and the highest-rated of the three Canadian models at UEF 4.20 per AHRI. In the factory Hybrid Standard mode it delivers an 82 US gallon (310 L) first-hour rating, which puts its delivery in the class of a typical gas tank while the heat pump does the everyday heating.
The heat pump runs only in 3–49 °C ambient air and the unit falls back to the elements outside that range. It cools and dehumidifies the room, needs a condensate drain and a 240 V circuit, and carries a 26 in (660 mm) jacket, so floor space and door openings are part of the specification. Whether CANRO stocks this model for a given job is confirmed at consultation.
Best suited to
- Families of four or more replacing an electric tank who want both capacity and low electricity use
- Conditioned basements and utility rooms with air volume to spare
- Households planning around BC's electric-tank-to-heat-pump rebate path
Limitations to know
- Heat pump needs 3–49 °C ambient air; cold garages run on the elements
- 26 in (610 mm) jacket and 280 lb (127 kg) shipping weight need space and access
- Requires a condensate drain and a suitable 240 V circuit
- Higher equipment cost than a resistance electric tank; rebates are verified per household
Applicability and support
- Model number
- RE2HP6510
- Variants on this page
- None
- Canadian availability
- available
- Production status
- current
- CANRO supplies
- Confirmed at consultation
- CANRO services
- Confirmed at consultation
- Recirculation
- Not published
- Warranty
- Series terms
Storage tanks can serve a recirculation loop with an external pump and return connection; Bradford White does not publish recirculation guidance for this model, so any loop is designed at consultation.
Where CANRO provides on-site service
On-site service is currently offered across Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, Maple Ridge, Pitt Meadows, White Rock, Tsawwassen; plus Anmore, Belcarra, Lions Bay, Bowen Island, Abbotsford with travel or ferry arrangements confirmed by phone. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Bradford White. Manufacturer gallon and BTU/h figures are preserved with metric alongside; notes flag conflicting documents and missing figures. Groups expand for detail.
Storage capacity 1
| Specification | Value | Note |
|---|---|---|
| Rated nominal capacity | 65 US gal (54 Imp. gal, 246 L) | Canadian sheet C1903. Nominal, not the tested storage volume. |
Delivery and recovery 3
| Specification | Value | Note |
|---|---|---|
| First-hour rating | 82 US gal (310 L) | Based on AHRI directory listings cited on C1903; hybrid operation. |
| Recovery at 90 °F (50 °C) rise, heat pump only | 6 US gal/h (23 L/h) | Hybrid Standard Mode basis at 67.5 °F ambient and 50% relative humidity per the sheet. |
| Recovery at 90 °F (50 °C) rise, heat pump plus element | 24 US gal/h (91 L/h) | Hybrid Standard Mode basis at 67.5 °F ambient and 50% relative humidity per the sheet. |
Efficiency 1
| Specification | Value | Note |
|---|---|---|
| Uniform Energy Factor (UEF) | 4.2 | Per AHRI listing cited on C1903. The sheet does not print the draw pattern; UEF values are not comparable across draw patterns. |
Connections 3
| Specification | Value | Note |
|---|---|---|
| Water connections | 3/4 in NPT true dielectric fittings | |
| Condensate connection | Drained through the condensate connection | Heat-pump operation produces condensate that must be drained. |
| T&P relief valve | Factory installed |
Electrical 2
| Specification | Value | Note |
|---|---|---|
| Backup elements | 4,000 W upper and 3,000 W lower, wired non-simultaneous | 240 V/208 V single phase per the sheet's general notes. |
| Electrical supply | 240 V/208 V, single phase, 60 Hz; dedicated circuit |
Physical 3
| Specification | Value | Note |
|---|---|---|
| Height to top of heater | 62 9/16 in (1589 mm) | 64 1/2 in (1638 mm) to the top of the air duct. |
| Jacket diameter | 26 in (660 mm) | |
| Shipping weight | 280 lb (127 kg) |
Operating limits 3
| Specification | Value | Note |
|---|---|---|
| Heat-pump ambient operating range | 3–49 °C (37–120 °F) | Outside this range the unit defaults to the electric elements per C1903. |
| Working pressure | 150 psi (1034 kPa); tested at 300 psi (2068 kPa) | |
| Certification | UL listed; CAN/CSA Z240 MH series approved for manufactured homes |
Other 1
| Specification | Value | Note |
|---|---|---|
| Anode rod | Protective anode, combined with the hot-water outlet |
Manuals
Maintenance the manufacturer specifies
- Clean the top-mounted washable air filter when the unit alerts; the sheet notes an automatic alert.
- Inspect the anode rod every 2 years and replace when depleted; more often with softened water.
- Operate the T&P relief valve at least once a year to check it lifts and reseats without leaking.
- Check the condensate drain for flow and blockage at least once a year; annual technician inspection.
Fault codes documented for this model
None documented yet.
Services
Hot water and scalding
- Water above 49 °C at a tap can scald in seconds, and children and older adults are at most risk. BC's plumbing code limits shower and bathtub water to 49 °C.
- Storage tanks are normally kept hotter (Health Canada advises 60 °C) to limit Legionella growth, with a thermostatic mixing valve tempering the water to the fixtures.
- Never bypass or remove a mixing valve, thermostat or high-limit control to get hotter water.
Official guidance: Government of Canada on water temperature and scalds and HealthLinkBC.
Frequently asked questions
Is the RE2HP6510 sold in Canada?
Yes. The AeroTherm G2 family is listed on Bradford White's Canadian heat-pump range and on Canadian spec sheet C1903. Bradford White sells only through wholesalers, so it is supplied and installed by contractors such as CANRO.
Why is the 65-gallon UEF higher than the 50-gallon?
Per the AHRI listings the sheet cites, the 65-gallon model rates UEF 4.20 against 3.89 for the 50-gallon; larger storage spreads the heat pump's fixed losses over more delivered water in the test.
Does the G2 need a condensate drain?
Yes. Heat-pump operation condenses moisture from the room air, and the tank has a condensate connection that must be drained to an approved location.
Questions about the Bradford White RE2HP6510?
Describe what the water heater is doing and get a straight answer about the next step.
On-site service in Metro Vancouver, BC. Call to check availability.
Sources and verification
- Canadian spec sheet C1903 · C1903 · Canadian source · accessed September 7, 2026
- Bradford White For The Pro — AeroTherm Series G2, Canada · Canadian source · accessed September 7, 2026