Bradford White RG1PV40S6N19

The Bradford White RG1PV40S6N19 is a 40 US gallon (151 L) through-the-wall power vent natural gas storage water heater with a 40,000 BTU/h input, 75 US gallon first-hour rating and UEF 0.68, sold in Canada under the current 19-suffix model numbers. It is the first-generation Defender power vent in a 20 in jacket.

CurrentSold in Canada

Key figures

Nominal capacity
40 US gal (33 Imp. gal, 151 L)
First-hour delivery
75 US gal (284 L)
Input
40,000 BTU/h
Uniform Energy Factor (UEF), medium draw
0.68
Natural gasPropanePower ventresidential

Nominal volume, rated volume and first-hour delivery are different figures; size by first-hour delivery.

Bradford White RG1PV40S6N19 in practice

The RG1PV40S6N19 is the 40-gallon member of the first-generation RG1PV power vent line, which Bradford White still lists in Canada alongside the second-generation RG2PV. At the same 40,000 BTU/h input and 75 US gallon (284 L) first-hour rating as the RG2PV40S6N, its differences are physical: a narrower 20 in (508 mm) jacket and a UEF of 0.68 against the RG2PV's 0.72, reflecting the older control generation.

It is a Defender Safety System flammable-vapour-ignition-resistant tank that vents through 2, 3 or 4 in PVC-family pipe under positive pressure, with no chimney required, and needs a 120 VAC, 3.1 A supply for the blower and electronic ignition. The current catalog number ends in 19 (RG1PV40S6N19); the Canadian spec sheet prints the same model as RG1PV40S6N. Whether CANRO stocks this model for a given job is confirmed at consultation.

Best suited to

  • Like-for-like replacement of an existing RG1PV power vent tank with a serviceable vent run
  • Narrow spaces where the 20 in jacket fits and a chimney is unavailable
  • Homes that want Defender flammable-vapour resistance without a flue

Limitations to know

  • Requires a 120 VAC receptacle; no hot water during a power outage
  • UEF 0.68 is below ENERGY STAR and below the RG2PV generation's 0.72
  • Blower and electronic control add points of failure the atmospheric line does not have
  • Warranty excludes labour and anode consumption; anode inspection every 2 years is required

Applicability and support

Model number
RG1PV40S6N19
Variants on this page
RG1PV40S6X19 (Propane, 38,000 BTU/h); RG1PV40S10N19 (10-year warranty version)
Canadian availability
available
Production status
current
CANRO supplies
Confirmed at consultation
CANRO services
Confirmed at consultation
Recirculation
Not published
Warranty
Series terms

Storage tanks can serve a recirculation loop with an external pump and return connection; Bradford White does not publish recirculation guidance for this model, so any loop is designed at consultation.

Where CANRO provides on-site service

On-site service is currently offered across Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, Maple Ridge, Pitt Meadows, White Rock, Tsawwassen; plus Anmore, Belcarra, Lions Bay, Bowen Island, Abbotsford with travel or ferry arrangements confirmed by phone. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Bradford White. Manufacturer gallon and BTU/h figures are preserved with metric alongside; notes flag conflicting documents and missing figures. Groups expand for detail.

Storage capacity 1
Bradford White RG1PV40S6N19 specifications: Storage capacity
SpecificationValueNote
Rated nominal volume40 US gal (33 Imp. gal, 151 L)Canadian sheet C1261. Nominal, not the tested storage volume.
Delivery and recovery 3
Bradford White RG1PV40S6N19 specifications: Delivery and recovery
SpecificationValueNote
First-hour rating75 US gal (284 L)Single column on C1261, not fuel-specific. Based on AHRI directory listing.
Recovery at 90 °F (50 °C) rise, natural gas43 US gal/h (36 Imp. gal/h, 163 L/h)Recovery efficiency up to 80% per Bradford White.
Recovery at 90 °F (50 °C) rise, propane (RG1PV40S6X19)41 US gal/h (155 L/h)
Input 2
Bradford White RG1PV40S6N19 specifications: Input
SpecificationValueNote
Input, natural gas40,000 BTU/h11.7 kW.
Input, propane (RG1PV40S6X19)38,000 BTU/h11.1 kW.
Efficiency 1
Bradford White RG1PV40S6N19 specifications: Efficiency
SpecificationValueNote
Uniform Energy Factor (UEF), medium draw0.68Per AHRI listing cited on C1261. Not ENERGY STAR (v5.0 requires UEF ≥ 0.81 for this size).
Venting and air 2
Bradford White RG1PV40S6N19 specifications: Venting and air
SpecificationValueNote
Vent connection2 in, 3 in or 4 in (51, 76 or 102 mm) PVC, ABS, CPVC or polypropyleneThrough-the-wall or vertical power venting under positive pressure.
Maximum equivalent vent length50 ft (15.2 m) in 2 in; 120 ft (36.6 m) in 3 in; 200 ft (61.0 m) in 4 inMinimum equivalent lengths are 7 ft in 2 in and 15 ft in 3 or 4 in; subtract 5 ft per additional 90° elbow.
Connections 3
Bradford White RG1PV40S6N19 specifications: Connections
SpecificationValueNote
Water connections3/4 in NPT with dielectric waterways and heat traps
Gas connection1/2 in (13 mm)
T&P relief valveFactory installed
Electrical 1
Bradford White RG1PV40S6N19 specifications: Electrical
SpecificationValueNote
Electrical supply120 VAC, 60 Hz, 3.1 APowers the AquaVENT blower and the ICON System control; no hot water during a power outage.
Physical 3
Bradford White RG1PV40S6N19 specifications: Physical
SpecificationValueNote
Height to top of heater46 1/2 in (1181 mm)55 7/16 in (1408 mm) to the top of the blower.
Jacket diameter20 in (508 mm)Depth 25 15/16 in (659 mm) including fittings.
Shipping weight140 lb (64 kg)
Operating limits 2
Bradford White RG1PV40S6N19 specifications: Operating limits
SpecificationValueNote
Working pressure150 psi (1034 kPa); tested at 300 psi (2068 kPa)
CertificationCSA International, ANSI Z21.10.1 / CSA 4.1
Other 1
Bradford White RG1PV40S6N19 specifications: Other
SpecificationValueNote
Anode rodMagnesium, combined with the hot-water outlet nipple

Manuals

Maintenance the manufacturer specifies

  • Inspect the anode rod every 2 years and replace when depleted; more often with softened water (manual, Maintenance item 9).
  • Operate the T&P relief valve at least once a year to check it lifts and reseats without leaking (item 6).
  • Drain about a gallon monthly to remove sediment (item 7); annual inspection by a qualified technician.
  • Inspect the vent system at least once a year; check burner flames twice a year (items 10 and 4).

Fault codes documented for this model

None documented yet.

Services

Hot water and scalding

  1. Water above 49 °C at a tap can scald in seconds, and children and older adults are at most risk. BC's plumbing code limits shower and bathtub water to 49 °C.
  2. Storage tanks are normally kept hotter (Health Canada advises 60 °C) to limit Legionella growth, with a thermostatic mixing valve tempering the water to the fixtures.
  3. Never bypass or remove a mixing valve, thermostat or high-limit control to get hotter water.

Official guidance: Government of Canada on water temperature and scalds and HealthLinkBC.

Frequently asked questions

Is the RG1PV40S6N19 sold in Canada?

Yes. The RG1PV power vent family is listed on Bradford White's Canadian residential gas page and on Canadian spec sheet C1261, which prints the model as RG1PV40S6N. The 19 suffix is the catalog form of the same current unit.

What is the difference between the RG1PV and RG2PV generations?

The RG2PV units carry the current control and rate UEF 0.72 against 0.68 for the RG1PV at the same input; the RG2PV short form also uses a wider 22 in jacket. Both are current in the Canadian catalog.

Can the RG1PV40S6N19 run on propane?

The propane version is the RG1PV40S6X19 with a 38,000 BTU/h input. Fuel conversion is not a field procedure; order the correct fuel version.

Questions about the Bradford White RG1PV40S6N19?

Describe what the water heater is doing and get a straight answer about the next step.

On-site service in Metro Vancouver, BC. Call to check availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.