Skip to content
WaterHeating.caby CANRO Heating & Cooling

Bradford White · Direct vent (RG2DV) · Gas storage tank

Bradford White RG2DV50H6N

The Bradford White RG2DV50H6N is a 48 US gallon (182 L) high-input direct vent natural gas storage water heater with a 50,000 BTU/h input, 96 US gallon first-hour rating and UEF 0.64, sold in Canada through wholesale channels. It is the highest-delivery model in the direct vent line.

CurrentSold in Canada

Key figures

Nominal capacity
48 US gal (40 Imp. gal, 182 L)
First-hour delivery
96 US gal (364 L)
Input
50,000 BTU/h
Uniform Energy Factor (UEF), medium draw
0.64
Natural gasPropaneDirect ventresidential

Nominal volume, rated volume and first-hour delivery are different figures; size by first-hour delivery.

Bradford White RG2DV50H6N in practice

The RG2DV50H6N is the high-input member of the Canadian direct vent family: a 48 US gallon tank with a 50,000 BTU/h burner that reaches a 96 US gallon (364 L) first-hour rating, roughly a quarter more than the standard 50-gallon direct vent model from a smaller nominal volume. Its 4 in x 6 in co-axial vent is larger than the 3 in x 5 in of the other models, and it carries 3/4 in side connections for space heating.

Like the rest of the family it is closed-combustion and needs no electricity: combustion air arrives through the outer vent pipe and the millivolt ICON control runs on the pilot's thermopile. The sheet calls for a minimum of 75 7/8 in from the floor to the vent centre-line, the tallest requirement in the family. UEF 0.64 is a medium-draw rating below ENERGY STAR. Whether CANRO stocks this model for a given job is confirmed at consultation.

Best suited to

  • Homes without a chimney that want near-tankless delivery from a gas tank with no electrical dependency
  • Potable plus space-heating applications on a sealed direct vent unit
  • Households of four or more with heavy peak-hour demand

Limitations to know

  • Minimum 75 7/8 in from floor to vent centre-line needs a tall wall at the termination
  • 4 in x 6 in co-axial vent uses the model-specific telescoping or flexible kits
  • UEF 0.64 is below ENERGY STAR; a condensing tank or tankless unit is more efficient
  • Warranty excludes labour and anode consumption; anode inspection every 2 years is required

Applicability and support

Model number
RG2DV50H6N
Variants on this page
RG2DV50H6X (Propane, 48,000 BTU/h); RG2DV50H10N (10-year warranty version)
Canadian availability
available
Production status
current
CANRO supplies
Confirmed at consultation
CANRO services
Confirmed at consultation
Recirculation
Not published
Warranty
Series terms

Storage tanks can serve a recirculation loop with an external pump and return connection; Bradford White does not publish recirculation guidance for this model, so any loop is designed at consultation.

Where CANRO provides on-site service

On-site service is currently offered across Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, Maple Ridge, Pitt Meadows, White Rock, Tsawwassen; plus Anmore, Belcarra, Lions Bay, Bowen Island, Abbotsford with travel or ferry arrangements confirmed by phone. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Bradford White. Manufacturer gallon and BTU/h figures are preserved with metric alongside; notes flag conflicting documents and missing figures. Groups expand for detail.

Storage capacity 2
Bradford White RG2DV50H6N specifications: Storage capacity
SpecificationValueNote
Rated nominal volume48 US gal (40 Imp. gal, 182 L)Canadian sheet C1105. Nominal, not the tested storage volume.
Rated (DOE) storage volume46 US gal (174 L)Published on the Canadian sheet C1105.
Delivery and recovery 3
Bradford White RG2DV50H6N specifications: Delivery and recovery
SpecificationValueNote
First-hour rating96 US gal (364 L)Single column on C1105, not fuel-specific. Based on AHRI directory listing.
Recovery at 90 °F (50 °C) rise, natural gas54 US gal/h (204 L/h)The sheet states 78% recovery efficiency for the family.
Recovery at 90 °F (50 °C) rise, propane (RG2DV50H6X)50 US gal/h (189 L/h)
Input 2
Bradford White RG2DV50H6N specifications: Input
SpecificationValueNote
Input, natural gas50,000 BTU/h14.7 kW. Highest input in the direct vent line.
Input, propane (RG2DV50H6X)48,000 BTU/h14.0 kW.
Efficiency 1
Bradford White RG2DV50H6N specifications: Efficiency
SpecificationValueNote
Uniform Energy Factor (UEF), medium draw0.64Per AHRI listing cited on C1105. Not ENERGY STAR (v5.0 requires UEF ≥ 0.81 for this size).
Venting and air 1
Bradford White RG2DV50H6N specifications: Venting and air
SpecificationValueNote
Vent connection4 in x 6 in (102 x 152 mm) co-axial direct ventLarger vent than the 40 and 50 S6N models; side-wall termination with the manufacturer's vent kits.
Connections 4
Bradford White RG2DV50H6N specifications: Connections
SpecificationValueNote
Water connections3/4 in NPT with dielectric waterways and heat traps
Space-heating connections3/4 in NPT side tappings (inlet and outlet)The model is listed for potable water and space heating.
Gas connection1/2 in (13 mm)
T&P relief valveFactory installed
Electrical 1
Bradford White RG2DV50H6N specifications: Electrical
SpecificationValueNote
Electrical supplyNone required (millivolt ICON System control powered by the pilot thermopile)
Physical 3
Bradford White RG2DV50H6N specifications: Physical
SpecificationValueNote
Height to top of heater59 3/16 in (1503 mm)Minimum 75 7/8 in (1927 mm) from the floor to the centre-line of the side-wall vent outlet.
Jacket diameter22 in (559 mm)Depth 31 in (787 mm) including fittings.
Shipping weight234 lb (106 kg)
Operating limits 2
Bradford White RG2DV50H6N specifications: Operating limits
SpecificationValueNote
Working pressure150 psi (1034 kPa); tested at 300 psi (2068 kPa)
CertificationCSA International
Other 1
Bradford White RG2DV50H6N specifications: Other
SpecificationValueNote
Anode rodMagnesium, combined with the hot-water outlet nipple

Manuals

Maintenance the manufacturer specifies

  • Inspect the anode rod every 2 years and replace when depleted; more often with softened water (manual, Maintenance item 9).
  • Operate the T&P relief valve at least once a year to check it lifts and reseats without leaking (item 6).
  • Drain about a gallon monthly to remove sediment (item 7); annual inspection by a qualified technician.
  • Inspect the vent system at least once a year; check burner flames twice a year (items 10 and 4).

Fault codes documented for this model

None documented yet.

Services

Hot water and scalding

  1. Water above 49 °C at a tap can scald in seconds, and children and older adults are at most risk. BC's plumbing code limits shower and bathtub water to 49 °C.
  2. Storage tanks are normally kept hotter (Health Canada advises 60 °C) to limit Legionella growth, with a thermostatic mixing valve tempering the water to the fixtures.
  3. Never bypass or remove a mixing valve, thermostat or high-limit control to get hotter water.

Official guidance: Government of Canada on water temperature and scalds and HealthLinkBC.

Frequently asked questions

Is the RG2DV50H6N sold in Canada?

Yes. It is listed on Bradford White's Canadian residential gas page and on Canadian spec sheet C1105. Bradford White sells only through wholesalers, so it is supplied and installed by contractors such as CANRO.

What does the H stand for in RG2DV50H6N?

The high-input form: 50,000 BTU/h against 42,000 on the standard 50-gallon direct vent model, giving a 96 rather than 77 US gallon first-hour rating at a smaller nominal volume.

Can the RG2DV50H6N run on propane?

The propane version is the RG2DV50H6X with a 48,000 BTU/h input. Fuel conversion is not a field procedure; order the correct fuel version.

Questions about the Bradford White RG2DV50H6N?

Describe what the water heater is doing and get a straight answer about the next step.

On-site service in Metro Vancouver, BC. Call to check availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

Call 604-359-1081Get Estimate