Bradford White · Power direct vent Defender (RG2PDV) · Gas storage tank

Bradford White RG2PDV40S6N

The Bradford White RG2PDV40S6N is a 40 US gallon (151 L) power direct vent natural gas storage water heater with a 40,000 BTU/h input, 75 US gallon first-hour rating and UEF 0.70, sold in Canada through wholesale channels. Twin-pipe closed combustion suits tightly sealed rooms with no chimney.

CurrentSold in Canada

Key figures

Nominal capacity
40 US gal (33 Imp. gal, 151 L)
First-hour delivery
75 US gal (284 L)
Input
40,000 BTU/h
Uniform Energy Factor (UEF), medium draw
0.7
Natural gasPropanePower direct ventresidential

Nominal volume, rated volume and first-hour delivery are different figures; size by first-hour delivery.

Bradford White RG2PDV40S6N in practice

The RG2PDV40S6N is the 40-gallon member of the Defender power direct vent family, built for the tightly insulated basement with no chimney and no combustion air to spare: a blower pulls outside air through one vent pipe and exhaust leaves through the other, up to 35 ft in 2 in or 85 ft in 3 in PVC-family pipe, with a concentric kit for a single wall exit. The intake run must never exceed the exhaust run.

It carries the Defender Safety System flammable-vapour-ignition-resistant design and the ICON System electronic control, which removes the standing pilot and lifts the medium-draw UEF to 0.70. The price is 110 VAC power for the blower and control, so hot water stops in an outage. Whether CANRO stocks this model for a given job is confirmed at consultation.

Best suited to

  • Tightly sealed homes and mechanical rooms with no chimney and limited combustion air
  • Homes without a chimney that want Defender flammable-vapour resistance
  • Like-for-like replacement of an existing twin-pipe power direct vent tank

Limitations to know

  • Requires 110 VAC power; no hot water during a power outage
  • Twin-pipe venting needs two wall penetrations or a concentric kit, and the intake cannot exceed the exhaust run
  • UEF 0.70 is below ENERGY STAR; a condensing tank or tankless unit is more efficient
  • Warranty excludes labour and anode consumption; anode inspection every 2 years is required

Applicability and support

Model number
RG2PDV40S6N
Variants on this page
RG2PDV40S6X (Propane, 38,000 BTU/h); RG2PDV40S10N (10-year warranty version)
Canadian availability
available
Production status
current
CANRO supplies
Confirmed at consultation
CANRO services
Confirmed at consultation
Recirculation
Not published
Warranty
Series terms

Storage tanks can serve a recirculation loop with an external pump and return connection; Bradford White does not publish recirculation guidance for this model, so any loop is designed at consultation.

Where CANRO provides on-site service

On-site service is currently offered across Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, Maple Ridge, Pitt Meadows, White Rock, Tsawwassen; plus Anmore, Belcarra, Lions Bay, Bowen Island, Abbotsford with travel or ferry arrangements confirmed by phone. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Bradford White. Manufacturer gallon and BTU/h figures are preserved with metric alongside; notes flag conflicting documents and missing figures. Groups expand for detail.

Storage capacity 1
Bradford White RG2PDV40S6N specifications: Storage capacity
SpecificationValueNote
Rated nominal volume40 US gal (33 Imp. gal, 151 L)Canadian sheet C1117. Nominal, not the tested storage volume.
Delivery and recovery 3
Bradford White RG2PDV40S6N specifications: Delivery and recovery
SpecificationValueNote
First-hour rating75 US gal (284 L)Single column on C1117, not fuel-specific. Based on AHRI directory listing.
Recovery at 90 °F (50 °C) rise, natural gas43 US gal/h (36 Imp. gal/h, 163 L/h)The sheet states 78% recovery efficiency.
Recovery at 90 °F (50 °C) rise, propane (RG2PDV40S6X)41 US gal/h (155 L/h)
Input 2
Bradford White RG2PDV40S6N specifications: Input
SpecificationValueNote
Input, natural gas40,000 BTU/h11.7 kW.
Input, propane (RG2PDV40S6X)38,000 BTU/h11.1 kW.
Efficiency 1
Bradford White RG2PDV40S6N specifications: Efficiency
SpecificationValueNote
Uniform Energy Factor (UEF), medium draw0.7Per AHRI listing cited on C1117. Not ENERGY STAR (v5.0 requires UEF ≥ 0.81 for this size).
Venting and air 2
Bradford White RG2PDV40S6N specifications: Venting and air
SpecificationValueNote
Vent connection2 in or 3 in (51 or 76 mm) twin pipe, PVC, ABS or CPVCClosed combustion: one pipe draws outside air, the other expels exhaust; concentric kit gives a single exit (subtract 10 ft from each pipe length).
Maximum vent length35 ft (10.7 m) in 2 in; 85 ft (26.0 m) in 3 in; minimum 7 ft (2.1 m)Subtract 5 ft per additional 90° elbow; the intake run cannot exceed the exhaust run.
Connections 3
Bradford White RG2PDV40S6N specifications: Connections
SpecificationValueNote
Water connections3/4 in NPT with dielectric waterways and heat traps
Gas connection1/2 in (13 mm)
T&P relief valveFactory installed
Electrical 1
Bradford White RG2PDV40S6N specifications: Electrical
SpecificationValueNote
Electrical supply110 VAC, 60 Hz, 3.1 APowers the combustion-air blower and the ICON System control; no hot water during a power outage.
Physical 3
Bradford White RG2PDV40S6N specifications: Physical
SpecificationValueNote
Height to top of heater49 9/16 in (1259 mm)59 7/8 in (1521 mm) to the exhaust connection.
Jacket diameter22 in (559 mm)Depth 32 3/8 in (822 mm) including fittings.
Shipping weight161 lb (73 kg)
Operating limits 2
Bradford White RG2PDV40S6N specifications: Operating limits
SpecificationValueNote
Working pressure150 psi (1034 kPa); tested at 300 psi (2068 kPa)
CertificationCSA International, ANSI Z21.10.1 / CSA 4.1
Other 1
Bradford White RG2PDV40S6N specifications: Other
SpecificationValueNote
Anode rodMagnesium, combined with the hot-water outlet nipple

Manuals

Maintenance the manufacturer specifies

  • Inspect the anode rod every 2 years and replace when depleted; more often with softened water (manual, Maintenance item 9).
  • Operate the T&P relief valve at least once a year to check it lifts and reseats without leaking (item 6).
  • Drain about a gallon monthly to remove sediment (item 7); annual inspection by a qualified technician.
  • Inspect the vent system at least once a year; check burner flames twice a year (items 10 and 4).

Fault codes documented for this model

None documented yet.

Services

Hot water and scalding

  1. Water above 49 °C at a tap can scald in seconds, and children and older adults are at most risk. BC's plumbing code limits shower and bathtub water to 49 °C.
  2. Storage tanks are normally kept hotter (Health Canada advises 60 °C) to limit Legionella growth, with a thermostatic mixing valve tempering the water to the fixtures.
  3. Never bypass or remove a mixing valve, thermostat or high-limit control to get hotter water.

Official guidance: Government of Canada on water temperature and scalds and HealthLinkBC.

Frequently asked questions

Is the RG2PDV40S6N sold in Canada?

Yes. It is listed on Bradford White's Canadian residential gas page and on Canadian spec sheet C1117. Bradford White sells only through wholesalers, so it is supplied and installed by contractors such as CANRO.

How is power direct vent different from direct vent?

Direct vent uses a co-axial pipe and natural draft with no power. Power direct vent uses a blower with twin pipes and needs 110 VAC, but it handles longer runs and the intake can be routed where co-axial kits cannot reach.

Can the RG2PDV40S6N run on propane?

The propane version is the RG2PDV40S6X with a 38,000 BTU/h input. Fuel conversion is not a field procedure; order the correct fuel version.

Questions about the Bradford White RG2PDV40S6N?