Skip to content
WaterHeating.caby CANRO Heating & Cooling

Bradford White · Defender Safety System atmospheric vent (RG2) · Gas storage tank

Bradford White RG250L6N

The Bradford White RG250L6N is a 48 US gallon (182 L) lowboy atmospheric-vent natural gas storage water heater with a 40,000 BTU/h input, 77 US gallon first-hour rating and UEF 0.63, sold in Canada through wholesale channels. The low, wide form fits under basement stairs and low joists.

CurrentSold in Canada

Key figures

Nominal capacity
48 US gal (40 Imp. gal, 182 L)
First-hour delivery
77 US gal (291 L)
Input
40,000 BTU/h
Uniform Energy Factor (UEF), medium draw
0.63
Natural gasPropaneAtmospheric (draft hood)residential

Nominal volume, rated volume and first-hour delivery are different figures; size by first-hour delivery.

Bradford White RG250L6N in practice

The L in RG250L6N stands for the lowboy form: 48 1/16 in (1221 mm) to the top of the heater, roughly 8 1/2 in shorter than the tall 50-gallon models, at the price of a 24 in (610 mm) jacket, the widest in the Defender atmospheric line. It stores 48 US gallons (182 L) nominal and, at a 40,000 BTU/h input, delivers a 77 US gallon (291 L) first-hour rating, within four gallons of the tall RG250T6N.

It vents by natural draft through a 3" or 4" draft hood, draws combustion air from the room and needs no electricity. Unlike the tall models it has no optional top temperature-and-pressure valve location, so the relief valve exits from the side. UEF 0.63 is a medium-draw rating below ENERGY STAR. Whether CANRO stocks this model for a given job is confirmed at consultation.

Best suited to

  • Under-stair utility closets, attics with low joists and basements with limited ceiling height
  • Like-for-like replacement of an existing lowboy 50-class atmospheric gas tank
  • Households of three to four people where the low form fits and a working chimney exists

Limitations to know

  • 24 in (610 mm) jacket needs floor width most tanks do not
  • No optional top T&P valve location on the lowboy form
  • UEF 0.63 is below ENERGY STAR; a power-vent, condensing tank or tankless unit is more efficient
  • Warranty excludes labour and anode consumption; anode inspection every 2 years is required

Applicability and support

Model number
RG250L6N
Variants on this page
RG250L6X (Propane, 38,000 BTU/h); RG250L10N (10-year warranty version)
Canadian availability
available
Production status
current
CANRO supplies
Confirmed at consultation
CANRO services
Confirmed at consultation
Recirculation
Not published
Warranty
Series terms

Storage tanks can serve a recirculation loop with an external pump and return connection; Bradford White does not publish recirculation guidance for this model, so any loop is designed at consultation.

Where CANRO provides on-site service

On-site service is currently offered across Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, Maple Ridge, Pitt Meadows, White Rock, Tsawwassen; plus Anmore, Belcarra, Lions Bay, Bowen Island, Abbotsford with travel or ferry arrangements confirmed by phone. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Bradford White. Manufacturer gallon and BTU/h figures are preserved with metric alongside; notes flag conflicting documents and missing figures. Groups expand for detail.

Storage capacity 2
Bradford White RG250L6N specifications: Storage capacity
SpecificationValueNote
Rated nominal volume48 US gal (40 Imp. gal, 182 L)Canadian sheet C1101. Nominal, not the tested storage volume.
Rated (DOE) storage volume47 US gal (178 L)Published on the US sheet 1101 only; not on the Canadian sheet.
Delivery and recovery 3
Bradford White RG250L6N specifications: Delivery and recovery
SpecificationValueNote
First-hour rating77 US gal (291 L)Single column on C1101, not fuel-specific. Based on AHRI directory listing.
Recovery at 90 °F (50 °C) rise, natural gas43 US gal/h (36 Imp. gal/h, 163 L/h)Recovery efficiency up to 80% per Bradford White.
Recovery at 90 °F (50 °C) rise, propane (RG250L6X)41 US gal/h (155 L/h)The Canadian sheet's Imperial-gallon figure for the propane row is not legibly aligned; the litre figure is shown.
Input 2
Bradford White RG250L6N specifications: Input
SpecificationValueNote
Input, natural gas40,000 BTU/h11.7 kW.
Input, propane (RG250L6X)38,000 BTU/h11.1 kW.
Efficiency 1
Bradford White RG250L6N specifications: Efficiency
SpecificationValueNote
Uniform Energy Factor (UEF), medium draw0.63Per AHRI listing cited on C1101. Not ENERGY STAR (v5.0 requires UEF ≥ 0.81 for this size).
Venting and air 1
Bradford White RG250L6N specifications: Venting and air
SpecificationValueNote
Vent connection3 in or 4 in (76 or 102 mm) draft hood"Snap Lock" 3x4 draft diverter; atmospheric venting into a suitable chimney or B-vent.
Connections 3
Bradford White RG250L6N specifications: Connections
SpecificationValueNote
Water connections3/4 in NPT with dielectric waterways and heat traps
Gas connection1/2 in (13 mm)
T&P relief valveFactory installed; no top location optionThe lowboy form does not offer the optional top T&P location.
Electrical 1
Bradford White RG250L6N specifications: Electrical
SpecificationValueNote
Electrical supplyNone required (ICON System control powered by the pilot thermopile)
Physical 3
Bradford White RG250L6N specifications: Physical
SpecificationValueNote
Height to top of heater48 1/16 in (1221 mm)51 9/16 in (1310 mm) to the exhaust connection.
Jacket diameter24 in (610 mm)Depth 27 1/2 in (699 mm) including fittings. Widest jacket in the Defender atmospheric line.
Shipping weight170 lb (77 kg)
Operating limits 2
Bradford White RG250L6N specifications: Operating limits
SpecificationValueNote
Working pressure150 psi (1034 kPa); tested at 300 psi (2068 kPa)
CertificationCSA International, ANSI Z21.10.1 / CSA 4.1
Other 1
Bradford White RG250L6N specifications: Other
SpecificationValueNote
Anode rodMagnesium, combined with the hot-water outlet nippleAluminum options listed in the Canadian parts list.

Manuals

Maintenance the manufacturer specifies

  • Inspect the anode rod every 2 years and replace when depleted; more often with softened water (manual, Maintenance item 9).
  • Operate the T&P relief valve at least once a year to check it lifts and reseats without leaking (item 6).
  • Drain about a gallon monthly to remove sediment (item 7); annual inspection by a qualified technician.
  • Inspect the vent system at least once a year; check burner flames twice a year (items 10 and 4).

Fault codes documented for this model

Services

Hot water and scalding

  1. Water above 49 °C at a tap can scald in seconds, and children and older adults are at most risk. BC's plumbing code limits shower and bathtub water to 49 °C.
  2. Storage tanks are normally kept hotter (Health Canada advises 60 °C) to limit Legionella growth, with a thermostatic mixing valve tempering the water to the fixtures.
  3. Never bypass or remove a mixing valve, thermostat or high-limit control to get hotter water.

Official guidance: Government of Canada on water temperature and scalds and HealthLinkBC.

Frequently asked questions

Is the RG250L6N sold in Canada?

Yes. It is listed on Bradford White's Canadian residential gas page and on Canadian spec sheet C1101. Bradford White sells only through wholesalers, so it is supplied and installed by contractors such as CANRO.

What does the L stand for?

The lowboy form: a shorter, wider tank made for spaces with limited height, such as under basement stairs. It trades about 8 1/2 in of height for about 2 in of jacket width versus the tall 50-gallon models.

Can the RG250L6N run on propane?

The propane version is the RG250L6X with a 38,000 BTU/h input. Fuel conversion is not a field procedure on this model; order the correct fuel version.

Questions about the Bradford White RG250L6N?

Describe what the water heater is doing and get a straight answer about the next step.

On-site service in Metro Vancouver, BC. Call to check availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

Call 604-359-1081Get Estimate